Vendor
Siemens
2 of 9 Siemens CVEs in Patchfirst (22%) are in CISA KEVThe US Cybersecurity and Infrastructure Security Agency’s list of Known Exploited Vulnerabilities. A CVE is added when CISA has evidence that attackers are using it. of vulnerabilities exploited in the wild.
- CVEs
- 9
- In CISA KEV
- 222%
- Known ransomware use
- 0
- Median days to KEV
- 968
- from publication
- Latest KEV listing
- 20 Oct 2026
Products
In KEVOther CVEs
- SIMATIC CP In KEV: 1 CVEs: 1
- Software Center In KEV: 1 CVEs: 1
- SIMATIC Drive Controller CPU 1504D TF In KEV: 0 CVEs: 3
- Industrial Edge Device Kit - arm64 V1.10 In KEV: 0 CVEs: 1
- SIMATIC Drive Controller family In KEV: 0 CVEs: 1
- SIMATIC IoT2050 Advanced In KEV: 0 CVEs: 1
- SINEMA Remote Connect Server In KEV: 0 CVEs: 1
Top ATT&CK techniques
What attackers do with Siemens CVEs- T1078Valid Accounts CVEs: 1
- T1059Command and Scripting Interpreter CVEs: 1
- T1574.008Path Interception by Search Order Hijacking CVEs: 1
- T1210Exploitation of Remote Services CVEs: 1
- T1499.004Application or System Exploitation CVEs: 1
Counts are Siemens CVEs linked to the technique. Each link’s provenance is on the CVE page.
Siemens CVEs
9 CVEs, by priority- CVE-2026-110936Siemens Software Center Uncontrolled Search Path Element VulnerabilitySiemens · Software CenterKEVMedium · 6.7T1078Valid AccountsT1059Command and Scripting Interpreter+1 more1.0%Top 38%65.0priority
- CVE-2026-58115A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running…Siemens · SIMATIC IoT2050 AdvancedCritical · 10.01.0%Top 39%64.3priority
- CVE-2016-8562Siemens SIMATIC CP 1543-1 Improper Privilege Management VulnerabilitySiemens · SIMATIC CPKEVHigh · 7.5T1210Exploitation of Remote ServicesT1499.004Application or System Exploitation3.6%Top 11%61.1priority
- CVE-2020-15782A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open…Siemens · SIMATIC Drive Controller familyCritical · 9.81 report5.2%Top 7.5%29.2priority
- CVE-2026-44415Affected systems do not properly restrict access to internal APIs and paths for authenticated usersSiemens · Industrial Edge Device Kit - arm64 V1.10Critical · 9.10.5%Top 59%16.9priority
- CVE-2026-63350Affected devices do not properly restrict executable content contained in imported trace filesSiemens · SIMATIC Drive Controller CPU 1504D TFCritical · 9.60.3%Top 73%14.4priority
- CVE-2026-63354Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before…Siemens · SIMATIC Drive Controller CPU 1504D TFCritical · 9.60.3%Top 76%13.8priority
- CVE-2026-63353Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on…Siemens · SIMATIC Drive Controller CPU 1504D TFCritical · 9.60.3%Top 76%13.8priority
- CVE-2019-13922A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1)Siemens AG · SINEMA Remote Connect Server0.6%Top 54%9.2priority